*47 PHONE SYSTEM SELECT
lfCent. Sta. /S A/OTona WATS line: [O= Pulse Dial]; l =Tone Dial
to
If Cent. Sta. /S on a WATS line: 2 = Pulse Dial :3 = Tone Dial.
48 REPORT FORMAT, PRIMARY/SECONDARY
Primary U Secondary U
[0. 3+1, 4+1 ADEMCO L/S STANDARD] 6 or undefined = 4+2 ADEMCO EXPRESS
1 = 3+1, 4+1 RADIONICS STANDARD
7 = ADEMCO CONTACT ID REPORTING
2 = 4+2 ADEMCO IJS STANDARD
8 = 3+1, 4+1 ADEMCO W EXPANDED
3 = 4+2 RADIONICS STANDARD 9 = 3+1, 4+1 RADIONICS EXPANDED
•1
TO SECONDARY
Others
Open/Close, Test
Al I
Al I
Al I
.—
*49 SPLIT/DUAL REPORTING
[0= Disable (Backup report only)]
TO PRIMARY
1 = Alarms, Restore, Cancel
2 = All except Open/Close, Test
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test
5= All
*5O 15 SEC DIALER DELAY (BURG) [0= no]; 1 = yes.
“O for UL installations.
tu
*5I
PERIODIC TEST REPORT [0= none]; 1 =24 hours; 2 = weekly; 3 = 30 days.
to
(Enter Test Code in field* 64. Reports with Partition 1 subscriber No.)
*52 TEST REPORT OFFSET O=24 houv 1 = 6 hours; [2= 12 hours]; 3 = 18 hours.
to
(Time to 1st report from programming or downloading).
*53 SESCOA/RADIONICS SELECT [0= Radionics (O-9, B-F reporting)]; 1 = SESCOA (O-9 only reporting)
Select Ofor all other formats.
t Entry
of a number other than one specified will give unpredictable results.
*56
ZONE ASSIGNMENT/ALARM REPORT CODES —This field is an interactive mode. Fill in the required data on the
worksheet below (and on next page) and follow the programming procedure in the installation manual.
ZONES ON CONTROL:
See explanation of headings on next page m
ZONE
ZONE
ZONE
PART’N ALARM RPT CODE INPUT RESPONSE
DESCRIPTION TYPE
No. Fe) TYPE
TIME
(Rj
(m
(P)
(In) (RT)
Wired Zone 1‘
m
Wired Zone 2
m
Wired Zone 3
m
Wired Zone 4
m
Wired Zone 5
m
Wired Zone 6
m
Wired Zone 7 t
m
Wired Zone 8“
m
Expansion Module
m
Supervision
Duress
m
Console Panic (1 & *, or A) ml
Console Panic (3& #, or C) ~~
Console Panic (*& #, or B) ml
Zone 1 can be used
as a 2-wire Fire zone.
*Zone 8 can be used as a Glassbreek zone.
$Zone 7 can be used for optional Keyswitch; shows as 77 for Zone Type (iT).
*m
I
m
Both
Both
Both
Both
I
Hw
Hw
I-fvv
Hw
Hw
Hvv
Hw
Hvv
.
EXPANS1ON ZONES:
Assign Zone Numbers (Zn) 10-17 to 421 9/4229 Auxiliary Wired Loops A–H, if used.
RF can use (Zn) 10-63 if 4219/4229 IS NOT used, (Zn) 18-63 if 421 9/4229 IS used
ZONE
ZONE
ZONE
DESCRIPTION
TYPE
(%
(m
PART’N
No.
(P)
ALARM RPT CODE
WeC;)
421 9/4229 Loop A, 1st Exp’n Zone ~( 111
B, 2nd
mm
c,
3rd
mm
D,
4th
mm
E,
5th
mm
0
n
n
u
0
I
I
I I
I
I
I
I I
I
I
I
I I
[
ENTER FOR
*RF ONLY*
INPUT
TYPE
(In)
n
n
n
n
n
LEARNED
RF INPUT
(L)
n
0
-3-