Programming Steps
1. Enter Programming mode
Programming mode can be entered in one of two ways.
a) Press both the [K] and [#] keys at the same time within 30 seconds after
power is applied to the Control. OR
b) Key the installer code, followed by depression of CODE [8] + O + O keys.
The factory installer code can be changed once in the program mode.
Immediately following entry into the program mode, the following will be
displayed on an Alpha console:
Program Mode
Fill # View -00
Fixed-word consoles will display: 00
Following the above display, the system is ready to be programmed for the
communication format parameters, or accept data entries. To begin data
entries, press [x] plus the first field number desired.
2. Set Standard Defaults
Once the Programming mode is entered, clear the system’s memory by
pressing 97, This ensures all program fields are set to their factory set, pre-
programmed values.
If desired, load one of the communication default
programming sets by entering one of the following code sequences:
TABLE OF DEFAULT PROGRAMMING COMMANDS
I PRESS I TO LOAD THIS DEFAULT SET
I
97 I
Loads standard default values for the panel
I
*94 *8O Low Speed communication defaults
*94 *81 Ademco Express communication defaults
*94 *82
Ademco High Speed communication defaults
*94 *83 Contact
ID communication defaults
Refer to the PROGRAMMING COMMUNICATION DEFAULTS section for
further instructions if one of the four communication default programming sets
is used.
3. Program the data fields
Program the appropriate phone numbers and account numbers, as well as
any other programming fields required to customize the system to the needs
of the installation. Refer to the PROGRAMMING FORM at the end of this
manual.
4. Enter Zone Descriptions (Alpha consoles only)
Refer to the PROGRAMMING ZONE DESCRIPTIONS section to enter zone
descriptors and a custom installer’s message.
5. Exit Programming Mode
When all fields have been entered and checked, and zone descriptors have
been assigned, exit programming mode by pressing either *98 or
99. A
second entry of
99 is required if the exit is being done from fields 1OOand
above. To prevent re-access to Programming mode using the Installer’s code,
use
98. The only way to re-access Programming mode is by depressing both
the [x] and [#] keys at the same time within 30 seconds of power up.
Exiting by using
99 always allows reentry into Programming mode using the
Installer’s code. Either way of exiting will allow access via downloading.