- 6 -
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (
59–
76, &
89):
With a 3+1 or 4+1 Standard Format:
Enter a code in the
first
box: 1–9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B,
"#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F.
A "0" (
not
"#+10") in the
first
box will disable a report.
A "0" (
not
"#+10") in the
second
box will result in automatic advance to the next field when programming.
With an Expanded or 4+2 Format:
Enter codes in
both
boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A "0" (
not
"#+10") in the
second
box will eliminate the expanded message for that report.
A "0" (
not
"#+10") in
both
boxes will disable the report.
With Ademco Contact ID Reporting:
Enter any digit (other than "0") in the
first
box, to enable zone to report (entries in the
second
boxes will be ignored).
A "0" (
not
"#+10") in the
first
box will disable the report.
Examples: For Code
3
(single digit), enter: 3 | 0
For Code
3 2
(two digits), enter: 3 | 2
For Code
B 2
(Hexadecimal), enter: #+11 | 2
SYSTEM STATUS REPORT CODES (
*
59–
*
68)
Field Function Programmed Values [ ] = Table 1 Default Value
59
EXIT ERROR REPORT CODE
[1]
2nd digit is automatically sent as 2nd digit of the zone alarm report
code programmed in
56, if expanded or 4+2 reporting is selected.
60
TROUBLE REPORT CODE
|
[1,0]
61
BYPASS REPORT CODE
|
[0,0]
62
AC LOSS REPORT CODE
|
[0,0]
63
LOW BAT REPORT CODE
|
[1,0]
64
TEST REPORT CODE
|
[1,0]
65
OPEN REPORT CODE
†† [0
] (††
2nd digit is automatically sent as the user
number if expanded
or 4+2 reporting is selected.)
66
ARM AWAY/STAY RPT CODE
†† [0,0]
AWAY STAY
67
RF XMTR LOW BAT REPORT CODE
|
[1,0]
68
CANCEL REPORT CODE
|
[1,0]
RESTORE REPORT CODES (
*
70–
*
76)
70
ALARM RESTORE RPT CODE
[1]
2nd digit is automatically sent as 2nd digit of the zone alarm report
code programmed in
56, if expanded or 4+2 reporting is selected.
71
TROUBLE RESTORE RPT CODE
|
[1,0]
72
BYPASS RESTORE RPT CODE
|
[0,0]
73
AC RESTORE RPT CODE
|
[0,0]
74
LOW BAT RESTORE RPT CODE
|
[1,0]
75
RF XMTR LO BAT RST RPT CODE
|
[1,0]
76
TEST RESTORE RPT CODE
|
[0,0]
Field Function Programmed Values[ ] = Table 1 Default Value
OUTPUT AND SYSTEM SETUP (
*
80–
*
92)
80
DEVICE PROGRAMMING MENU MODE
81
ZONE LISTS MENU MODE
Program *80 and *81 only if Powerline Carrier Devices or chime by
zone are to be used. See procedure later in this manual.
83
ENHANCED SEQUENTIAL MODE. See procedure later in this manual.