EXPLANATION OF ZONE ASSIGNMENT TABLE HEADINGS
Zn = ZONE NO.
Zone Nos. are from 01 to 06, 09 to 35, 92, 95, 96, 99. Some are pre-assigned.
With Field
25 set for auxiliary wired loops (4219, or 4229), use Zone Nos. 1017 for loops AH.
With Field
22 set for RF (5800), use Zone Nos. 10-35.
ZT = ZONE
TYPE
00 = Not Used
01 = Entry/Exit #1
02 = Entry/Exit #2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24-Hr Silent
07 = 24-Hr Audible
08 = 24-Hr Aux
09 = Fire
10 = Interior w/Delay
12 = 24-Hour Monitor
20 = ArmStay
21 = ArmAway
22 = Disarm
23 = No Alarm Response
24 = Silent Burglary
DEFAULT VALUES
Zn:
01 02 03 04
ZT:
[09] [01] [01] (03)
Zn:
05 06 99
ZT:
[03] [03] [07]
RC = ALARM REPORT CODE
Two Hex Digits. For each Hex Digit, enter: 0009 for 09, 10 for A, 11 for B, 12 for C, 13 for
D, 14 for E, 15 for F. If 00 is entered as the first digit, there will be no report for that zone.
For contact ID reporting, this is an enabling code only. Enter any hex digit (other than 00) in
the first pair of boxes. The second pair of boxes are ignored.
In = LOOP
INPUT TYPE
HW: Hard Wire
AW: Aux Wire (4219 or 4229)
Enter 2 for AW: Auxiliary wired
Enter 3 for RF: Supervised RF
Enter 4 for UR: Unsupervised RF
Enter 5 for BR: Button Type RF
Hardwire zone input
types are automatically
assigned.
RT = RESPONSE TIME
0 = 10mSec; 1 = 350mSec; 2 = 700mSec. Default Values for zones 01 06 = 1 (350mSec)
L = LEARNED RF INPUT
Used with 5800 RF Loop Input Devices. Record transmitter input number.
SYSTEM STATUS REPORT CODES (
59
68)
TO PROGRAM SYSTEM STATUS & RESTORE
REPORT CODES (
59
76, &
89):
With a 3+1 or 4+1 Standard Format:
Enter a code in the
first
box: 19, 0, B, C, D, E, or F. Enter #+10 for 0, #+11 for B, #+12
for C, #+13 for D, #+14 for E, #+15 for F.
A 0 (
not
#+10) in the
first
box will disable a report.
A 0 (
not
#+10) in the
second
box will result in automatic
advance to the next field when programming.
With an Expanded or 4+2 Format:
Enter codes in
both
boxes
(1st and 2nd digits) for 19, 0, or BF, as described above.
A 0 (
not
#+10) in the
second
box will eliminate the expanded
message for that report.
A 0 (
not
#+10) in
both
boxes will disable the report.
With Ademco Contact ID Reporting:
Enter any digit (other
than 0) in the
first
box, to enable zone to report (entries in the
second
boxes will be ignored).
A 0 (
not
#+10) in the
first
box will disable the report.
Examples:
For Code
3
(single digit), enter: 3 | 0
For Code
3 2
(two digits), enter: 3 | 2
For Code
B 2
(Hexadecimal), enter: #+11 | 2
59
EXIT ERROR REPORT CODE [0]
60
TROUBLE REPORT CODE
[00]
|
61
BYPASS REPORT CODE
[00]
|
62
AC LOSS REPORT CODE
[00]
|
63
LOW BAT REPORT CODE
[00]
|
64
TEST REPORT CODE
[00]
|
65
OPEN REPORT CODE
[0]
66
ARM AWAY/STAY RPT CODE
[00]
††
AWAY STAY
2nd digit is automatically sent as the 2nd digit of the
zone alarm report code programmed in
56, if expanded
or 4+2 reporting is selected.
†† 2nd digit is automatically sent as the user number if
expanded or 4+2 reporting is selected.
67
RF XMTR LOW BAT REPORT CODE [00]
|
68
CANCEL REPORT CODE [00]
|