Shrnutí obsahu

Strany 1 - 9,3

9,39LVWD,QWHUDFWLYH3KRQH0RGXOH,QVWDOODWLRQDQG6HWXS*XLGH®N6431-3V1 10/99

Strany 2

4286 VIP Module Installation and Setup Guide2-2Wiring Connections1. Make 12V (+), Ground (–), Data in, and Data out connections from the4286 VIP Modu

Strany 3 - Table of Contents

Section 2. Mounting and Wiring2-3Do NOT connect speakers in parallel.Do NOT use a single 4-ohm speaker.Damage to the 4286 may result.Special Wiring N

Strany 4

4286 VIP Module Installation and Setup Guide2-4

Strany 5 - General Description

3-1SECTION 3Programming••••••••••••••••••••••••••••••••••••••••••In This Section♦ Programming the Control for 4286 VIPModule Usage♦ Entering the 4286

Strany 6 - Control Panels Supported

4286 VIP Module Installation and Setup Guide3-2Entering the 4286 VIP Module Programming Mode:1. Pick up a premises touch tone phone connected to the

Strany 7

Section 3. Programming3-3• Field 00: Monitored Keypad AddressThis field enables or disables the 4500 thermostat AND speaker output fea-tures and sel

Strany 8

4286 VIP Module Installation and Setup Guide3-42. Enter the same address in this fieldIn a system that uses non-addressable keypads:Set this field to

Strany 9 - Mounting and Wiring

Section 3. Programming3-5installation where descriptors have already been programmed, check to besure that those descriptors can be annunciated by th

Strany 10 - Wiring Connections

4286 VIP Module Installation and Setup Guide3-6Programming NoteBe sure that all programming changes made to the control are uploaded viaADEMCO’s V–LIN

Strany 11 - Special Wiring Notes:

Section 3. Programming3-7Programming Relay Voice DescriptorsWith some controls, certain lights/appliances can be turned on and off via thetelephone u

Strany 13 - Programming

4286 VIP Module Installation and Setup Guide3-8RELAY VOICE DESCRIPTORS VOCABULARY & CUSTOM WORD SUBSTITUTES(4286 VIP Module only)Table 3-2The Word

Strany 14 - Programming Notes

Section 3. Programming3-9When programming or making test calls to emergency numbers, briefly explainto the dispatcher the reason for the call. Perfo

Strany 15

4286 VIP Module Installation and Setup Guide3-10Table 3-3 (cont’d)SPEAKER CONTROLCATEGORIES DESCRIPTIONWARNINGS:1 = Yes, 0 = NoControls all sounds i

Strany 16 - Programming Zone Descriptors

4-1SECTION 4Basic Operating Guide••••••••••••••••••••••••••••••••••••••••••In This Section♦ Phone Code♦ Setting the PhoneCode ♦ Phone Access When On-P

Strany 17 - Systems with Alpha Keypads

4286 VIP Module Installation and Setup Guide4-2If the code is not accepted, there will be no system status report heard. Thecontrol may have been acti

Strany 18 - Programming Note

Section 4. Basic Operating Guide4-33. Enter the 4-digit system security code. As a safety feature, there is a 3-try limit in which to enter each co

Strany 19

4286 VIP Module Installation and Setup Guide4-4A list of confirmation sounds and voice announcements that follow successfulcommand entries is provided

Strany 20 - Table 3-2

Section 4. Basic Operating Guide4-5Remote Access CAN be turned OFF from an off-premises phone, butCANNOT be turned ON.If Remote Phone Access has bee

Strany 21 - Table 3-3

4286 VIP Module Installation and Setup Guide4-6End User Relay Command Mode WhenUsing the 4286 VIP ModuleFor information on whether operation of the en

Strany 22 - (cont’d)

Section 4. Basic Operating Guide4-7Using the Phone Panic FeatureOn-premises Touch-tone phones wired as shown in the 4286 “Summary ofConnections” can

Strany 23 - Basic Operating Guide

iTable of Contents••••••••••••••••••••••••••••••••••••••••••Section 1. GENERAL DESCRIPTION ...

Strany 24 - Phone Access When On-Premises

4286 VIP Module Installation and Setup Guide4-8About the Speaker OutputPressing “✴ ✴” on the monitored keypad will trigger a status announcementfrom t

Strany 25 - Performing System Commands

5-1SECTION 5Troubleshooting••••••••••••••••••••••••••••••••••••••••••In This Section♦ Typical System Problems and Solutions•••••••••••••••••••••••••••

Strany 26 - Telephone Confirmation

4286 VIP Module Installation and Setup Guide5-2Remote Phone Access Keeps Turning OffAutomatically.• Improper keying (or attempted tampering)from an ou

Strany 27

Section 5. Troubleshooting5-3In a 4140XMP Installation, Descrip-tions of Zones Annunciated Are NotCorrect.• In an existing 4140XMP installation, allz

Strany 28 - Using the 4286 VIP Module

4286 VIP Module Installation and Setup Guide5-46. If there is incorrect programming ofRF zones for the 4281 or 5881 Re-ceiver. If more RF zones have b

Strany 29 - Using the Novice Voice Menu

A-1SECTION 6Appendices••••••••••••••••••••••••••••••••••••••••••In This Section♦ In the Event of Trouble with Regular Telephone Service♦ Federal Commu

Strany 30 - About the Speaker Output

4286 VIP Module Installation and Setup GuideA-2FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 STATEMENTThis equipment has been tested to FCC requirem

Strany 31 - Troubleshooting

Section 6. AppendicesA-3TELCO-PROVIDED COIN SERVICE ADVISEMENT:This equipment cannot be used on telephone company-provided coin service. Connection t

Strany 32

4286 VIP Module Installation and Setup GuideA-4YELLOWNO CONNECTIONREDBLACKGREENTO CONTROL PANEL KEYPAD CONNECTIONSKEYEDHEADER1 2345 6 7NOCONNECTION428

Strany 33

ADEMCO LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidi-aries and affiliates ("S

Strany 34

Table of Contents (cont'd)iiSection 5. TROUBLESHOOTING...

Strany 35 - Appendices

165 Eileen Way, Syosset, New York, 11791Copyright © 1999 PITTWAY CORPORATION¬19QlN6431-3V1 10/99

Strany 36

1-1SECTION 1General Description••••••••••••••••••••••••••••••••••••••••••In This Section♦ Application and Description♦ Control Panels Supported ♦ Diff

Strany 37 - Section 6. Appendices

4286 VIP Module Installation and Setup Guide1-2When connected, the 4286 VIP Module will enable the user to do the follow-ing via any Touch-tone teleph

Strany 38 - Summary of Connections

Section 1. General Description1-3®The 4500 thermostat cannot be used in UL installations.• Synthesized voice prompts to instruct the user on how to i

Strany 39 - ADEMCO LIMITED WARRANTY

4286 VIP Module Installation and Setup Guide1-4

Strany 40 - ¬19Ql

2-1SECTION 2Mounting and Wiring••••••••••••••••••••••••••••••••••••••••••In This Section♦ Mounting the 4286 VIP Module♦ Wiring Connections♦ Speaker Co

Komentáře k této Příručce

Žádné komentáře