SPECIFICATIONS:
165 Eileen Way, Syosset, NY 11791
Copyright ©2002 Pittway Corporation
ADEMCO is an ISO9001 Registered
Company
Communication Formats
Supports the following formats for the primary and
secondary central station receivers:
• ADEMCO Low Speed (Standard or Expanded)
• ADEMCO High Speed
• ADEMCO Contact ID
Sescoa/Radionics
• Long Range Radio interface (ECP)
• ADEMCO Express
Improved Downloading Features
• Uploads and downloads at 300 baud, making
upload/download speed faster
• Ability to upload peripheral devices, their physical
addresses, programmed addresses, and firmware
revision levels from the control
CCTV: Switcher Module
• VistaView100
Access Control:
• VistaKey (addressable) Access Control
Module
• VistaKey-SK Starter Kit (Canada use
VistaKey CNSK)
• VistaKey-EX Expansion Kit
• VGM Vista Gateway Module to PassPoint Access
Control (Northern Computers) supports up
to 32 doors
Agency Listings
• UL609 Grade A Local Mercantile Premises and
Mercantile Safe and Vault*
• UL611/UL1610 Grades A, AA Central Station*
• UL365 Grades A, AA Police Connect*
• UL985 Household Fire*
• California State Fire Marshall (CSFM)
• CUL Household Fire/Burglary, and also
Commercial Burglary
• UL1023 Household Burglary
* Requires Vista-ULKT Attack Resistant Enclosure
Commercial
Burglary/CCTV
and Access
Control
Platform
L/V128BCN/D Rev. 3/02
VISTA-128B
Physical:
14-1/2" W X 18" H X 4.3" D
Electrical:
• Voltage Input: From ADEMCO No. 1361 Plug-In
Transformer (use 1361CN in Canada) or 4300
transformer (for X-10 installations) rated 16.5VAC,
40 VA (For Canada use 1361CN transformer
w/PSC04 for X-10 installations)
• Alarm Sounder Output: 10VDC-13.8VDC, 1.7
amps max., (UL1023, UL609 installations); 750mA
less aux. current draw (UL985 installations)
• Auxiliary Power Output: 9.6VDC-13.8VDC,
750mA max. For UL installations, the accessories
connected to the output must be UL Listed, and
rated to operate in the above voltage range
• Backup Battery: 12VDC, 4AH or 7AH gel cell.
YUASA NP4-12 (12V, 4AH) or NP7-12 (12V,
7AH) recommended
• Standby Time: 4 hours min. with 750 mA aux. load
using 7 AH battery
• Circuit Protectors: PTC circuit breakers are used
on battery input to protect against reverse battery
connections and on alarm sounder output to
protect against wiring faults (shorts). A solid state
circuit breaker is used on auxiliary power output to
protect against wiring faults (shorts)
Digital Communicator
• Formats Supported: ADEMCO High Speed,
ADEMCO 4 + 2 Express, ADEMCO Low Speed,
ADEMCO Contact ID, Sescoa and Radionics
Low Speed
Line Seize:
Double Pole
Ringer Equivalence:
0.7B
FCC Registration No.:
AC398U-68192-AL-E
IC Industry Canada
6139 Remote Keypads/6160 Alpha Keypad
• Physical:
– Width: 6.25 inches
– Height 4.75 inches
– Depth: 1.25 inches
• Electrical:
– Voltage Input: 12VDC
– Current Drain: 100 mA
• Interface Wiring:
– RED: 12VDC input (+) auxiliary power
– BLUE: Not used
– GREEN: Data to control panel
– YELLOW: Data from control panel
– BLACK: Ground and (-) connection from
supplemental power supply
Optional Equipment:
See ADEMCO Group control accessories
compatibility chart for complete list.
• 4100APG Alpha Paging
• 7845C AlarmNet Control Channel
Cellular Radio
• 7820 Long Range Radio (7830RCN
in Canada)
• 4286 VIP Module
• 5881 RF Receivers
• Powerline carrier devices
• 6220S Serial Printer
ORDERING:
Part No. Description
VISTA-128B Commercial Partitioned Burglary Alarm Control Platform
VISTA-128CN
(In Canada)
Zobrazit stránku 2