Field Function
Programmed Values [ ] = Table 1 Default Value
42
SECONDARY PHONE NUMBER
Enter up to 24 digits; Do not fill unused spaces. If fewer than 24 digits
entered, pressing
advances to the next field. To clear entries from
field, press
41
.
!
All four digits of the subscriber account number must be entered in Fields
43 and
44. If ten digit format is
selected in
48 (option 5), all ten digits of the Subscriber Account number must be entered.
For fields
43,
44:
Enter 4 to 10 digits.
Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter
as 4th digit, if 3+1
dialer reporting is to be used. If only 3 digits used, pressing
advances to the next field. Enter [
] as the fifth digit if a 4-
digit account number (for 3+1, CID®) is used.
To clear entries from field, press
43
or
44
. Examples:
For Acct. 1234, enter: 1 | 2 | 3 | 4
; For Acct. B234, enter: #+11| 2 | 3 | 4 For Acct. 1234567890, enter:
1| 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 0 ; For Acct. 123, enter: 1 | 2 | 3 |
43
PRIMARY SUBS ACCT #
See note above.
44
SECONDARY SUBS ACCT #
See note above.
For field 46
Enter up to 24 digits. Enter 0-9, #+11 for ‘’; #+12 for ‘#’; #+13 for a pause (two seconds).
46
“FOLLOW ME” REMINDER
PHONE NUMBER
Enter up to 24 digits; Do not fill unused spaces. If fewer than 24 digits
entered, pressing
advances to the next field. To clear entries from
field, press
46
.
47
PHONE SYSTEM SELECT
[5]
Central
Dialing Mode
Station Pulse Tone Pulse Tone
No WATS 0 = No Speaker
Phone
1 = No
Speaker Phone
4 = With
Speaker Phone
5 = With
Speaker Phone
WATS 2 = No Speaker
Phone
3 = No
Speaker Phone
6 = With
Speaker Phone
7 = With
Speaker Phone
48
REPORT FORMAT for PRIM./SEC
[7, 7]
Primary Secondary
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = ADEMCO CONTACT ID® REPORTING WITH 10-DIGIT SUBS ACCT NO.
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID® REPORTING WITH 4-DIGIT SUBS ACCT NO.
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
Entering a number other than the one specified may give unpredictable results.
Note: If you are using Pulse (rotary) Dialing, you must
enter the numbers slowly to allow the pulse dialer
time to o
p
erate.
Note: Option 5 or 7 (ADEMCO Contact ID®)
must be selected for AVM.