Field Function
Programmed Values[ ] = Table 1 Default Value
90
EVENT LOGGING
[3]
0 = None; 1 = Alarm/Alarm Restore; 2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore; 8 = Open/Close.
Example: To select “Alarm/Alarm Restore”, and “Open/Close”, enter
9 (1 + 8); To select all, enter #15.
Note: System messages are logged when any non-zero selection is made.
91
ALARM AUDIO VERIFICATION
(AAV)/REMOTE PHONE CONTROL
[2]
0 = None
1 = AAV and remote phone control
2 = remote phone control only
4 = AAV only
Notes:
(1) In order to activate the remote phone access feature and defeat an
answering machine ensure that the correct ring detection count (“15”)
has been programmed in field
95.
(2) Remote phone session will be terminated if a report must be sent.
(3) If an alarm will be reported to primary and secondary phone numbers,
AAV can only function via the secondary number.
(4) If an alarm will be reported to a pager (6-8 in field
49), or the follow me
phone number (10-12 in field
49), AAV cannot be used.
92 NUMBER OF REPORTS IN ARMED
PERIOD
[0]
0 = 10 Alarm/Alarm Restore Reports;
1 = Unlimited (UL installations = 0)
DOWNLOAD INFORMATION (
93,
94,
95)
93 FLEXIBLE CALLBACK
[0]
0 = No flexible callback; 1 = Last digit flexible; 2 = Last 2 digits
flexible;
3 = Last 3 digits flexible
94
DOWNLOAD PHONE NUMBER
Enter up to 20 digits, 0–9; #+11 for '
'; #+12 for '#'; #+13 for a
pause. Do not fill unused spaces. If fewer than 20 digits entered,
pressing
advances to the next field. To clear entries from field,
press
94
.
Note: In UL installations, downloading may only be performed if a technician
is at the site.
95
RING DETECT COUNT FOR
DOWNLOADING/REMOTE PHONE
CONTROL MODE
[15]
0 = Disable Station Initiated Download; 1–14 = number of
rings (1–9, [#]+10 =10, [#] +11 =11, [#] +12 =12, [#] +13
=13, [#] +14 =14); 15 = answering machine defeat ([#] +15
=15)
96
INITIALIZE DOWNLOAD ID &
SUBSCRIBER ACCOUNT
No entry required
97
SET ALL PROGRAM FIELDS TO
1 OF 4 SETS OF DEFAULT VALUES
Enter 1-4 to select from default tables 1-4
Enter 0 to abort.
98
EXITS PROGRAMMING MODE
(PREVENTS RE-ENTRY)
If 98 is used to exit programming mode, you cannot enter the
Installer Code + 8+ 0 + 0 for re-entry. You must press "" and
"#" within 50 seconds of power up or from exiting Programming
mode to re-enter Programming mode.