POWERLINE CARRIER DEVICES WORKSHEET FOR
*
80, and
*
81.
Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feature is used.
U
L
Powerline Carrier Devices are not UL Listed for fire or burglary functions and are intended for home
automation.
80
OUTPUT DEVICES
Fill in the required data on the worksheet on below and follow the programming procedure in the Installation Instructions as
you enter the data during the displays and prompts that appear in sequence.
Note
:
Field
25 must be programmed with a House Code.
START
either or both
STOP
either or both
DEVICE
NUMBER
ACTION
(aa)
EVENT ZONE
TYPE
(et)
LIST
(zl)
ZONE TYPE
SYS OPERATION (zt)
RESTORE
ZONE LIST (zl)
ZONE TYPE/
SYS OPERATION (zt)
P.L.C.D.
*†
01
P.L.C.D.
*†
02
P.L.C.D.
*
03
P.L.C.D.
*
04
P.L.C.D.
*
05
P.L.C.D
.*
06
SYS. P.L.C.D.
*
07
SYS. P.L.C.D.
*
08
[2]
[33]
[36]
* P.L.C.D. = Powerline Carrier Device (X-10).
Note:
If using an X-10 Powerhouse Security SH10A Siren as device 8, you must change the action default to “3” if using default table 4.
Where:
A = DEVICE ACTION
0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
ET = EVENT TYPE
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
Z L = ZONE LIST
1, 2, or 3 (from Field
81) or 0 = Not Used.
"START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will
START. "STOP"
RESTORE
of
ZONE LIST: Upon restore of ALL zones on this list, device
action will STOP. It need not be same list as used for START.
Note:
Do not assign zones with types 20, 21, or 22 to a zone list.
ZT = ZONE TYPE/
SYSTEM OPERATION
Choices for Zone Types are:
00 = Not Used 04 = Interior Follower 08 = 24 Hr Aux
01 = Entry/Exit#1 05 = Trouble Day/Alarm Night 09 = Fire Zone
02 = Entry/Exit#2 06 = 24 Hr Silent 10 = Interior w/Delay
03 = Perimeter 07 = 24 Hr Audible 24= Silent Burglary
Choices for System Operation are:
20 = Arming–Stay 33 = Any Alarm (except ZT=08) 42 = System Battery Low
21 = Arming–Away 36 = *At Bell Timeout 43 = Communication Failure
22 = Disarming (Code + OFF) 38 = Chime 52 = Kissoff
31 = End of Exit Time 39 = Any Fire Alarm 58 = Duress
32 = Start of Entry Time 40 = Bypassing
* Or at Disarming, whichever occurs earlier.
Note:
In normal operation mode:
For Devices 1-6: For Devices 7 and 8:
N = device (unit) number
Function + Lights On + N Code + Function + 4 + N
(Entry
starts
Device N)
Function + Lights Off + N Code + Function + 7 + N
(Entry
stops
Device N)
Note
:
Any
zone in "ZT" going into alarm, fault, or trouble will
activate device with the exception of 01, 02 when the system
is in alarm.
Any
zone that restores will stop device action.