Field Function
Programmed Values[ ] = Table 1 Default Value
91
LYNXR/LYNXR24
LONG RANGE RADIO/ALARM
AUDIO VERIFICATION
(AAV)/REMOTE PHONE CONTROL
[4]
0 = Long range radio only
1 = AAV and remote phone control
2 = Long range radio and remote phone control
4 = AAV only
Notes:
(1) If long range radio is being connected alarm audio verification cannot be
used.
(2) In order to activate the remote phone access feature and defeat an
answering machine ensure that the correct ring detection count (“15”)
has been programmed in field *95.
(3) Remote phone session will be terminated if a report must be sent.
(4) If alarm audio verification mode is selected a long range radio cannot be
connected.
(5) Alarm audio verification will only function when Contact ID is selected
and cannot be used for UL installations.
(6) If an alarm will be reported to the end user phone number (6-8 or 10-12
in field *49) AAV cannot be used.
(7) If AAV is enabled, LYNX will automatically use the central station phone
number programmed in field *41. If AAV is not enabled LYNX will use
the phone number programmed in field *42.
(8) If AAV is enabled, reports will be sent to the two-way voice phone
number.
LYNXR-EN
ALARM AUDIO VERIFICATION
(AAV)/REMOTE PHONE CONTROL
[4]
0 = None
1 = AAV and remote phone control
2 = remote phone control only
4 = AAV only
Notes:
(1) No programming is required if connecting an ALARMNET 7845C device
because the option is always enabled.
(2) In order to activate the remote phone access feature and defeat an
answering machine ensure that the correct ring detection count (“15”)
has been programmed in field *95.
(3) Remote phone session will be terminated if a report must be sent.
(4) Alarm audio verification will only function when Contact ID is selected
and cannot be used for UL installations.
(5) If an alarm will be reported to the end user phone number (6-8 or 10-12
in field *49) AAV cannot be used.
(6) If AAV is enabled, LYNX will automatically use the central station phone
number programmed in field *41. If AAV is not enabled LYNX will use
the phone number programmed in field *42.
(7) If AAV is enabled, reports will be sent to the two-way voice phone
number.
92
NUMBER OF REPORTS IN ARMED
PERIOD
[0]
0 = 10 Alarm/Alarm Restore Reports;
1 = Unlimited (UL installations = 0)
DOWNLOAD INFORMATION (
*
93,
*
94,
*
95)
93
FLEXIBLE CALLBACK
[0]
0 = No flexible callback; 1 = Last digit flexible; 2 = Last 2 digits flexible;
3 = Last 3 digits flexible
94
DOWNLOAD PHONE NUMBER
Enter up to 20 digits, 0–9; #+11 for '
'; #+12 for '#'; #+13 for a pause.
Do not fill unused spaces. If fewer than 20 digits entered, pressing
advances to the next field. To clear entries from field, press
94
.
Note:
In UL installations, downloading may only be performed if a technician
is at the site.