Testing and Maintaining the System
Testing the System (to be conducted weekly)
Test mode allows each protection point to be checked for proper operation.
The keypad sounds a single beep every 40 seconds as a reminder that the system is in the Test mode.
Alarm messages are not sent to your Central Station while Test mode is on.
1 Disarm the system and close all
protected windows, doors, etc.
The READY indicator light should come on if all zones are intact
(i.e., all protected windows, doors, etc. are closed.
2. Security Code+ [5] then [0]
(walk)
Starts Test mode.
The Dial test (option “1”) is intended for the installer and should
not be used unless directed to do so by your Security System
Representative
If, during these tests, a problem is experienced with any
protection point (no confirming sounds, no display), call for
service immediately.
3. Listen. The external sounder should sound for 1 second and then turn
off. If the sounder does not sound, CALL FOR SERVICE.
4. Fault zones. Open each protected door and window in turn and listen for three
beeps from the keypad. Identification (zone number or zone
description) of each faulted protection point should appear on the
display. The display clears when the door or window is closed.
5. Walk in front of any interior
motion detectors (if used) and
listen for three beeps.
The identification of the detector should appear on the display when
it is activated. The display clears when no motion is detected.
Note that if wireless motion detectors are used, there is a 3-minute
delay between activations. This is to conserve battery life.
6. Test all smoke detectors, following
the manufacturer's instructions
The identification of each detector should appear on the display
when each is activated.
7. Exit test mode:
Security Code+ [1]
When all protection points have been checked and are intact
(closed), there should be no zone identification numbers displayed on
the keypad.
If the test mode is inadvertently left active, it automatically turns
off after 4 hours. During the final five minutes, the keypad emits a
double beep every 30 seconds.
Maintaining the System
In The Event Of Telephone Operational Problems
In the event of telephone operational problems, disconnect the control from the phone line by removing the plug
from the phone wall jack. We recommend that your installer demonstrate this disconnection on installation of
the system. Do not attempt to disconnect the phone connection inside the control. Doing so could result in the
loss of your phone lines. If the regular phones work correctly after the control has been disconnected from the
phone wall jack, the control has a problem and you should immediately call for service. If upon disconnection of
the control, there is still a problem on the phone line, notify the Telephone Company that they have a problem
and request prompt phone repair service. The user may not under any circumstances attempt any service or
repairs to the security system. Repairs must be made only by authorized service (see the LIMITED WARRANTY
statement for information on how to obtain service).