options.
The discussion that follows broadly divides those options
into two categories: control options and comnunicator options.
conmacwmns:
1.
2.
3.
4.
l
5.
6.
Entry IMy, Exit Way
The entry delay is the time between entering the premises and when
the system must be disarmed to avoid activating an alarm. The exit
delay is the time between arming the system and when the premises
must be exited to avoid activating an alarm.
The entry and exit
delays may be independently PROM selected to be between 0 and 135
seconds in 15 second increments.
Exterior SouJlder/Priwry a1cator IWay
The system may be set up to delay the activation of the exterior
bell and/or siren (optional plug-in 4165 siren driver module required).
In addition, triggering of the connnunicator may be additionally delayed.
This feature may be used to reduce false alarms due to operator errors.
The delay may be set in PROM between 0 and 135 seconds in 15 second
increments, but applies only to those zones that have the delay feature
enabled (See No. 15).
fkll/Siren Timeout
Bell/Siren audible indication may be PROM selected to last between
0 and 36 minutes in 4 minute increments, after which it "times out".
At hwmr Last Timer
To eliminate nuisance power failure central station and local audible
reports, the system may be PROM programed to ignore short duration
outages.
This delay in reporting an AC loss condition may be set
between 0 and 36 minutes in 4 minute increments (As an example,
if a timeout period of 16 minutes was selected, power outages of
less than 16 minutes will be ignored -
the POUER LED will extinguish
inmediately, however).
mry/Exlt zane Selection
The system allows a choice of zones that may be set up with entry/exit
delay.
Zones 1, 2, and 3, individually or in any combination, may
be set up in PROH as entry/exit zones (For example, if the interior
zone [zone 33 wtre set up with space protection, choosing an entry/exit
delay on this zone would allow space protection devices to include
the entry door in their area of protection which is to say, they
could be held off during the normal entry/exit period).
Fast Response Zone Wection
Fast (15 msec) response is used for certain devices (such as glass
break detectors and some photoelectrics) that cannot be used with
a normal (250 mxc) response zone.
Fast response cm be PRM designated
for zones 2, 3 and 4, individually or in any combination.
628-4