PROGRAMMING THE SECURITY CONTROL
Installer options are
stored in non–removable, electrically erasable. non–
volatile EEPROM memory.
These options
must be programmed for the particular
installation to establish its specific alarm and reporting features.
The security control may be programmed from
an optional 5137 or 4137 remote
console,
or can be programmed locally from the 699 Programmer.
Information
regarding the Programmer is
included with the No. 695–30XT Programming
Cartridge.
When programming from the 5137 console,
prompts for each field description (only
field number will. be displayed on the 4137 console) and field number will be
displayed on the 2–line, 32–character LCD display; also, each entry is displayed
as it is keyed in. After programming,
values that have been entered in each
field can be reviewed and, if neccesssary, modified.
The system is factory–programmed to a set of preset values, which can be altered
by the installer to
suit the specific needs of a particular installation or
installation company. The preset values are detailed in the Factory Programming
Table.
Note:
Programming information is stored in non–volatile 3EPROM memory in the
control (removal of power will not result iv the 10SS of the
information). Consequently,
it is possible to program the system at
any time even at
the installer’s premises prior to the actual
installation.
Simply apply power temporarily ?a ‘:he control and the~
program the unit as desired.
When programming from the console, note the following:
1.
Enter the Programming mode by simultaneously depressil~; The * and # keys
within 30 seconds after pwer is applied to the Control, or subsequently k.y
keying the code 4 + 1 + 4 + O followed by depression of CODE + O + O keys.
Once an installer code is programmed,
use it instead of 4140 to gain access
to the programming mode.
2. Immediately following entry into the program mode, the following will be
displayed on a 5137:
Program Console
* Fill # View 00
and on a 4137: 00
To program a data field, key * PIUS Address (for example, *01), then make
the required entry. To simply rwiew a data field, key # plus Address.
3.
When a data field has been completely programmed, the console will “beep”
three times and then automatically proceed to, and display, the next data
field address to be programmed.
4. If the number of digits that you enter in the data field is less than the
maximum permitted (for example,
phone number), then the console will
display the last data entered.
To proceed, the next data field address to
be programmed must then be entered (for example, *05).
5.
If an address is improperly entered, the console will display FC . If a
program entry is improperly entered (for example, a larger number than that
which is permitted),
the console display will go blank.
In either case,
simply re–enter the number.
The following is a description of commands necessary for programming: