6. Subscriber #0135 User #7 bypasses
faulted zone 2 (for the sake of this
example, Zone 2 =
Channel 3, not a requisite) and then arms the system.
Subscriber Channel Number
Identification
1234
56789
Message:
0135
5515 5 5 5 5 3 (Bypass Report)
0135
7444
4 4 4 4 4 (Closing Report)
Bypass restorals are transmitted when the restoral takes place.
0135
5535
55553
7. If a trouble condition occurs in Zone 4 for subscriber #5890 and Zone 4 was
assigned to Channel 2,
a trouble report is transmitted.
Subscriber
Channel Number
Identification
1234
56789
Message:
5890
5155 55555
Trouble restoral is transmitted as soon as it occurs.
5890
5355
55555
8.
If a systm trouble condition occurs, a separate trouble message format
exists.
Subscriber Channel Number
Identification
1234
56789
For Loss of AC Reporting (Channel 1 is used)
Message:
0135 1555
For AC Restored.
Message: 0135 3555
For Lou Battery Reporting (Channel 2 is used)*
Message: 0135 5155
For L- Battery Restorsl
Message:
0135 5355
For Program Tamper (Channel 3 is used)
Message:
0135 5515
For P-er Up Reset (Channel 4 is used)
Message:
0135 5551
*
Low battery is not only determined when AC
55556
55556
55556
55556
55556
55556
Dower is off and the batterv is
being discharged. It is also tested for by priodicd.ly (at the interval
selected in Address *27) removing AC power briefly to check battery status.
NOTE: Restorals are not applicable to Program Tamper and Power Up Reset.