ADEMCO Vista-128B PLUS Průvodce nastavením Strana 11

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 72
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 10
– 11 –
#13 for 2-second pause
2*83 PAGER 8 ID NUMBER
Enter the pager 8 ID number. Up to 10 digits. Press * after
the last digit if less than 10 is required.
2*84 PAGER 8 FORMAT [0]
0= Numeric; 1=ID; 2=Alphanumeric
2*85 PAGER 8 DELAY 1 [000] | |
Enter the delay time 000-060 seconds. The delay occurs
between the phone number and the pager ID.
NOTE: Program only if using numeric format.
2*86 PAGER 8 DELAY 2 [000] | |
Enter the delay time 000-060 seconds. The delay occurs
between the pager ID and the event information.
NOTE: Program only if using numeric format.
2*87 PAGER 8 PARTITION ENABLE
1
2
3
4
5
6
7
8
1=enable; [0=disable]
2*88 PAGER 8 TRIGGER EVENT ENABLES
Alarm
Trbl
Byp
O/C
Syst
1=enable; [0=disable]
SUMMARY OF PROGRAMMING COMMANDS
To enter program mode, enter installer code + [8] + [0] +
[0] + [0]
To set standard defaults, press *97
To change to next page of program fields, press *94
To return to previous set of fields, press *99
To erase account and phone number field entries,
press [*] + field number + [*]
To assign zone descriptors, press #93 + follow menu
prompts
To add custom words, press #93 + follow menu prompts
To enter Installer's Message, press #93 + follow menu
prompts
To exit program mode, enter *99 OR *98: *99 allows re-
access to programming mode by installer code. *98
prevents re-access to programming mode by installer
code.
Zobrazit stránku 10