The 6139/6160 Keypad displays the following prompts, which are sent by the Long Range Radio transmitter to the control.
Note: These prompts are for the 7820 Radio only. If you are using a different radio, refer to the radio’s instructions for
the correct prompts.
PROMPT
EXPLANATION
DEVICE ADDRESS
Enter the device address of the radio. The default address is 3.
ID #
(1234)
Enter the 4-digit customer account number, 0001-9999. This ID number will appear in the messages
generated by the radio. Messages generated by the panel and transmitted by the radio will contain the ID
number programmed into the panel. The radio and the panel should have the same ID number, if possible.
If a different 4-digit customer account number is used in the radio than is programmed into the alarm control,
the radio will transmit radio-specific messages (power-on reset, AC fail, etc.) using the radio customer
number, and alarm messages using the control panel’s customer number. If these numbers are different,
you will be billed for two AlarmNet radio accounts.
PROMPT
EXPLANATION
ODD [Y/N]
(N)
Enter Y for odd system flag; N for even system flag.
Alarmnet (Y/N)
(Y)
Enter Y if this is an AlarmNet installation. Enter N if this is a private system and skip to Question 7.
CS ID
(11)
Enter the primary central station’s system ID number, 1-7F (will not be displayed for private system users).
BAT PRESENT [Y/N]
(N)
Enter Y if optional battery will be used. Must be Y for UL installations (a battery must be installed).
USE RADIO # [Y/N]
(N)
If you selected Y, the Radio ID number replaces the panel Subscriber ID in panel-generated messages.
If you selected N, the radio sends panel-generated messages with the panel Subscriber ID number.
2
ND
CS ID
(12)
This must be programmed with a value, even if it is the same as the primary central station. The
alarm panel has the option of sending a selected message to the second central station.
REVIEW (Y/N)
(N)
Enter Y to review the programming options and to ensure that the correct responses have been made.
Parameters can be changed during review.
Enter N to end programming session.
Panel Linking Module
PROMPT
EXPLANATION
01 PANEL ID#
(01-08) 01
If you selected device type 10 (panel linking module), this prompt appears. Enter the panel’s ID # (01-08).
Each panel must have its own unique ID #. This device is supervised as zone “8xx,” where “xx” = the
device’s address. If you want to supervise this device, program that zone with response type 05.
If you want to supervise panel link modules from other controls, also program them into
Zone Programming
on a regular zone (001-250) with a response type of 14.
Press [✱] to accept entry.