SECTION XII
103
USING TEST MODE
Dgors and windows
0
Motion detectors
Smoke detectors
Turning off TEST mode
SECTION
TESTING THE
XII
SYSTEM
After the installation is completed, the Security System should be thoroughly
tested as follows:
1. With the System in the disarmed state, check that all zones are intact. If
DISARMED - Press r] to show fautts (5137) or NOT READY (4137) is
displayed, press the [‘I key to display the descriptors of the faulted
zone(s). Restore faulted zone(s) if necessary, so that “‘*DISARMED”’
READY TO ARM (5137) or READY (4137) is displayed.
2. Enter the security code and press the TEST key. The external sounder (if
used) should sound for 3 seconds and then turn off (the system is
operating on the backup battery only at this time).
NOTE 1. The system will not enter the Test mode il the battery voltage is
too low, if the battery is not connected, or if any communication
messages are waiting to be transmitted.
NOTE 2. As a reminder that the system k in the Test mode, the Console
will sound a single beep at lbsecond intervals if no protection zones are
violated.
NOTE 3. In the Test mode, no alarm reports will be sent to the central
station. Also, the external sounder (if used) will not be activated.
Open and close each protected door and window in turn. Each action should
produce three beeps from the Console. The descriptor for each protection
zone will appear on the Console display.
Walk in front of any interior motion detectors
Listen for three beeps when the
detector senses movement. While it is activated, its descriptor will remain
displayed on the Console. Note that wireless PlRs will have a 3 minute
lockout between transmissions to consewe battery life
Follow the test procedure provided by the manufacturer of each smoke
detector to ensure that all detectors are operational and are functioning
pmwriy..
NOTE: A 2-w& smoke detector display will not clear until the Test mode is
exited.
Enter the security code and press the OFF key.
ADEMCO’s VISTA Xhf SERIES TECIiNXCAL REFERENCE MANUAL