Section 15. ZONE PROGRAMMING (*56 Menu Mode)
While in program mode, press *
56 to enter Zone Programming Menu
Mode.
Refer to the zone assignment table for
*
56 on the separate programming
form .
This is an interactive menu mode that is used to program zone numbers,
zone types, partition numbers, alarm and report codes, and to identify the
type of loop input device. This mode can also be used for entering Alpha
descriptors for zones (we recommend entering descriptors in menu mode
*
82).
After entering
*
56, the following prompts are displayed:
Enter Zn Num.
(00 = Quit) 10
Zone 20 entered -
Zone Number (Zn): Enter the zone number that you wish to program (or
00 to exit zone programming). Press [
*
] to continue.
Zn ZT P RC In: L
10 03 1 10 AW: 1
A summary display appears, showing the status of that zone's
programming.
If it is programmed satisfactorily, press [#] to back up one step and enter
another zone number, if desired.
If the zone is not programmed, or you want to make changes, press [
*
] to
continue.
¯ Zone Number
10 Zone Type
Perimeter 03
Zone Type -
Zone Type (ZT): Each zone must be assigned to a zone type, which
defines the way in which the system responds to faults in that zone.
Enter the zone type code (or change it, if necessary). Zone types are
listed below.
00 = Not Used
01 = Entry/Exit #1
02 = Entry/Exit #2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire W/verif.
10 = Interior w/Delay
23 = No Alarm
Response
24 = Silent Burglary
Default values for zones 01 to 08 are:
Zone No.(Zn): 01 02 03 04 05 06 07 08
Zone Type Default: 09 01 03 03 03 03 03 03
Partition Default 1 1 1 1 1 1 1 1
Response Time
Default * 1 1 1 1 1 1 1 1
* “1” for response time = 350 msec.
Press [
*
] to continue.
10 Partition
1
Partition No. (P) (Default = [1].
Enter "1" or "2".
Press [
*
] to continue.
10 Report Code
1st 00 2nd 00 00
Report Code (RC): The report code consists of 2 hexadecimal digits,
each in turn consisting of 2 numerical digits. For example, for a report
code of "3C", enter [0][3] for "3" and [1][2] for "C".
Enter the numbers and press [
*
] to continue.