Section 22. TESTING THE SYSTEM
Test Procedure
After installation is completed, each partition of the Security System should be
carefully tested, as follows.
1. With the System in the disarmed state, check that all zones are intact. If a NOT
READY message is displayed, press the [
*
] key to display the faulted zone(s).
Restore faulted zone(s) if necessary, so that READY message is displayed. Fault
and restore every sensor individually to assure that it is being monitored by the
system.
2. Enter the security code and press the TEST key. The outside sounder will
sound for 1 second. The keypad should sound 3 beeps each time a contact is
faulted. A test report should be transmitted (if programmed) to the Central
Station immediately. If the backup battery is discharged or missing, the sounder
may not turn on and a LOW BATTERY report will be transmitted with a TEST
report. The keypad will beep once per minute as a reminder that the system is in
the Test Mode. To turn off the test mode enter security code and press the OFF
key.
Alarm messages will be sent to the central station during the following tests 3
and 4. Notify them in advance that tests will be in progress.
3. Arm the system and fault one or more zones. After 15 seconds (if optional dialer
delay is selected), silence alarm sounder(s) by entering the code and pressing
OFF. Check Entry/Exit delay zones.
4. Check the keypad-initiated alarms that are in the system by pressing the Panic
key (key pairs on some keypads) . If the system has been programmed for
audible emergency, the keypad will emit a steady alarm sound, and ALARM and
zone number will be displayed. Silence the alarm by entering the security code
and pressing OFF.
If the system has been programmed for silent emergency, there will be no
audible alarms or displays, but a report will be sent to the central station.
5. If output Relay Units/Powerline Carrier Devices have been installed, test their
programmed action.
6 Notify the central station when all tests are finished, and verify results with them.
NOTE: THE TEST MODE WILL BE AUTOMATICALLY TERMINATED AFTER 4
HOURS IF THE INSTALLER OR USER DOES NOT MANUALLY
TERMINATE IT.
This insures that Fire and Panic zones will not remain disabled.
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the
user are vital to continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing and offering a regular maintenance
program to the user as well as acquainting the user with the proper operation and limitations of
the alarm system and its component parts. Recommendations must be included for a specific
program of frequent testing (at least weekly) to insure the system's proper operation at all times.