48–
DOWNLOAD
INFORMATION
(
*
94,
*
95)
*
94 DOWNLOAD PHONE NUMBER
Ê | | | | | | | | | | | | | | |
Enter up to 16 digits as follows: 0–9, # +11 for “
*
”, # + 12 for “#”, # + 13 for
a pause. Do not fill unused spaces. End field by entering
*
. To clear
entries from field, press
*
94
*
.
*
95 RING DETECTION COUNT FOR DOWNLOADING 0
0-15 = number of rings before control picks up phone line
Refer to the chart below and program this field accordingly.
NOTE: If "15" is entered
in field *95 to bypass an
answering machine, and
a 4285 Phone Module is
included in the system,
you should note the
following:
When calling in from an
off-premises phone, the
user should make the
initial call, allow 1 to 3
rings only, then hang up.
The user should then call
again. The Phone
Module will now seize
the line, and 2 long tones
sound, followed by the
usual voice prompt for
the 2-digit access code.
If this procedure is not
followed, Phone Module
operation will not be
possible.
ÊPhone Answering
Module ÊÊMachine Downloading Field
*
95
Yes No No Set for value other than “0” (1–14). This
will enable the control panel to answer the
phone call. Otherwise, it will not be possible to access the Phone
Module
Yes Yes No Set for a value higher than the number of
rings for which the answering machine is set.
Example: if machine is set for 4 rings, use a value of 5 or higher. This
is recommended so that the Phone
Module can still be accessed if the answering
machine is turned off and does not
answer the phone call.
Yes No Yes Set for value other than “0” (1–14).
Yes Yes Yes Enter “15” to bypass answering machine.
No No No Enter “0”.
No Yes No Enter “0”.
No No Yes Enter 1–14.
No Yes Yes Enter 15. See note at left.
OTHER PROGRAMMING
COMMANDS
*
56 ZONE PROGRAMMING MODE
Interactive menu mode used for programming zone attributes and report
codes. Refer to
ZONE PROGRAMMING
section for procedure.
*
80 OUTPUT DEVICES
Interactive menu mode applicable only if field *25 is programmed for a
4229, 4204, or if Powerline Carrier devices are being used. Refer to the
OUTPUT DEVICES
section for detailed procedure.
*
81 ZONE LISTS FOR OUTPUT DEVICES
Interactive menu mode applicable only if *25 is programmed for a 4229,
4204, or if Powerline Carrier devices are being used. Refer to the
ZONE
LIST
section for detailed procedure.
*
82 CUSTOM ALPHA EDITING
Interactive menu mode used to program zone descriptors. Refer to the
ALPHA DESCRIPTION PROGRAMMING
section for procedure.
*
96 INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. No. FOR
DOWNLOADING
Pressing *96 initializes the system for downloading.
*
97 SET ALL PROGRAM FIELDS TO DEFAULT VALUES
Pressing
*
97 automatically loads all defaults and erases any information
previously programmed.
*
98 EXITS PROGRAMMING MODE
Prevents re-entry by : Installer Code + 8 + 0 + 0
Allows re-entry only by Power-up then [
*
] and [#].
*
99 EXITS PROGRAMMING MODE
Allows re-entry to program mode by: Installer Code + 8 + 0 + 0 or
by Power-up then [
*
] and [#].