Interactive Mode Programming (
56, *57,
58,
79,
80,
81,
82)
Entering Interactive Mode
Press [
] + [Interactive Mode No.] (for example,
56) while in Program Mode.
The Alpha display keypad will display the first of a series of prompts
requesting entries.
After making the appropriate entry, press the [
] key to accept the entry and
continue to the next prompt.
Loading Factory Defaults/Initializing for Download
To Load Default Entries
Press
97 while in Program Mode. This resets all data fields to the default
values shown on the Program Form. Use
97 only if you wish to return to the
original factory-programmed defaults.
To Initialize Download ID
Press
96 while in Program Mode. This initializes the system for
downloading and resets all the subscriber account numbers and CSID.
Do not press
97 to load defaults if any programming has been done previouslydata already
programmed into the system will be changed!
Exiting the Programming Mode
Prevent installer code reentry
Press
98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if
98 was
used to exit, you must first power the system down. Then power up again,
and press [
] and [#] at the same time, within 50 seconds of powering up.
See field *88 for other Program mode lockout options.
Allow installer code reentry
Press
99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [
] and [#] at the same time,
within 50 seconds of power-up.
Table of Device Addresses
This Device Uses Address
Reports as
††
Enabled By
RF Receiver 00 100 *56 zone programming: input device type entry
Long Range Radio 03 103 automatic if output to long range radio field *29 enabled
4286 Voice Module 04 104 automatic if phone module access code field *28 enabled
Zone Expanders (4219/4229):
module 1 (for zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 zones 33 - 40
module 5 zones 41 - 48
07
08
09
10
11
107
108
109
110
111
*56 zone programming: input device type entry, then:
automatic if zone no. 9-16 entered as AW type or relay assigned
automatic if zone no. 17-24 entered as AW type or relay assigned
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
automatic if zone no. 41-48 entered as AW type or relay assigned
Relay Modules (4204):
module 1
module 2
module 3
module 4
12
13
14
15
112
113
114
115
*79 output device programming: device address prompt:
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
data field programming as listed below:
always enabled for partition 1, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
5800TM Module 28 n/a automatic
4219/4229 addresses 9-11 and 4204 addresses 14-15 apply to the VISTA-20P.
†† Addressable devices are identified by 1” plus the device address when reporting. Enter a report
code for zone 91 to enable addressable device reporting (default = reports enabled). See field *199
for addressable device (ECP) 3-digit/2-digit identification keypad display options.
Installation Instructions
3-6