Various System Trouble Displays
Alpha Display Fixed Disp. Meaning
CANCELED ALARM CA
will appear if an exit or interior zone contained a fault during closing at the time
the Exit Delay ended (e.g., exit door left open), but the system was disarmed
during the Entry Delay time. The alarm sounder and keypad sound continuously,
but stop when the system is disarmed. No message will be transmitted to the
central station.
EXIT ALARM EA
will appear when the Exit Delay ends if an exit or interior zone contained a fault
during closing. The alarm sounder and keypad sound continuously until the
system is disarmed (or timeout occurs). An Exit Alarm message is sent to the
central station. Also results if an alarm from an exit or interior zone occurs
within 2 minutes after the end of an Exit Delay.
CHECK CHECK
indicates that a problem exists with the displayed zone(s) and requires attention.
Note: The control will sense a high resistance in the loops on hardwired zones 28
and display CHECK and the affected zone number when the system is in the
disarmed mode. It will not be possible to arm the system as long as this condition
exists (unless this zone is bypassed). If the system is in the armed mode when the
high resistance condition occurs, this display will not appear, but will do so as
soon as the system is disarmed. Check the sensor or the loop wiring for the
displayed zone.
ALARM 1xx 1xx
indicates that communication between control and a zone expander or wireless
FAULT 1xx 1xx
receiver is interrupted, where xx is the device address. Check the wiring and
CHECK 1xx 1xx
DIP switch settings on the units.
91
If field *199 is set to 1, all ECP module problems are displayed as 91.
If there are wireless sensors in the system, the Check condition may also be
caused by some change in the environment that prevents the receiver from
receiving signals from a particular sensor.
SYSTEM LO BAT BAT
with no zone number indicates that the system's main standby battery is weak.
LO BAT BAT
with a zone number and a once-per-minute beeping at the keypad indicates that a
low-battery condition exists in the wireless sensor displayed (zone 00 indicates a
wireless keypad). If the battery is not replaced within 30 days, a CHECK
display may occur.
NOTE: Some wireless sensors contain a non-replaceable long-life battery which
requires replacement of the entire unit at the end of battery life (e.g., Nos. 5802,
5802CP).
TELCO FAULT 94
Telephone Line Failure, indicates that a monitored telephone line (if programmed
in field *92) has been cut or disconnected. Depending on how the system was
programmed, the keypad may also produce a trouble sound, and the external
sounder may be activated. Silence by entering installer code + OFF.
Busy-Standby dl
If this remains displayed for more than 1 minute, the system is disabled.
Modem Comm CC
The system is in communication with the central station for change of function or
status verification.
no display no display
Power Failure
If there is no keypad display at all and the LEDs are unlit, operating power (AC
and battery) for the system has stopped and the system is inoperative.
If the message AC LOSS (Alpha display keypads) or NO AC (Fixed-Word
display keypads) is displayed, the keypad is operating on battery power only.
If the battery standby capacity is used up during a prolonged AC power outage,
the control's power will shut down to minimize deep discharge of the battery.
Comm. Failure FC
A communication failure has occurred.
Open Circuit OC
The keypad is not receiving signals from the control and sees an open circuit.
Long Rng Trbl bF
Backup LRR communication failure.
Bell Failure
70
Bell supervision failure.
RCVR Jam
90
RF jam detected.
KEYPAD LOW BAT 00 BAT
Wireless keypad low battery
Phone Okay Cd
The dialer test has been successful (CID code 601).
Dialer Off dO
The dialer is disabled.
Test in Progress dd
Walk test mode is active(CID code 607).
Upload Completed dC
The upload or download session was completed.
Upload Failed dF
The upload or download session failed before completion.