Section 22 – Data Field Descriptions
22-15
1*73 PRINTER BAUD RATE
[0]
Enter 0 if printer is set for 1200 baud (preferred).
Enter 1 if printer is set for 300 baud.
Note: Must be
1
if using the alpha numeric pager interface.
1*74 RELAY TIMEOUT XXX MINUTES [000]
||
Enter the relay timeout, 000-127 in multiples of 2 minutes, desired for #80 Menu Mode
time-driven event relay command numbers "04/09" and Relay Programming in the #93
Menu Mode Programming output command "56" (refer to #93 Menu Mode and
Scheduling sections in this manual).
1*75 RELAY TIMEOUT YYY SECONDS [000]
||
Enter the relay timeout, 000-127 seconds, desired for #80 Menu Mode time-driven event
relay command numbers "05/10" Relay Programming in the #93 Menu Mode
Programming command "57" (refer to #93 Menu Mode and Scheduling sections in this
manual).
1*76 ACCESS RELAY # # (partition-specific) [00]
|
The system can be programmed to provide user-activated access control. If enabled, the
assigned relay will pulse for 2 seconds when the user enters his code and presses 0.
Enter the relay number (00-32) for the relay that will be used for access control. Enter
00 if not used in this partition. This function has not been UL Listed for use with the
VISTA-128B control. Must be 00 for UL installations.
*Note: See the Access Control section for enhanced access control capability.
2*00 NUMBER OF PARTITIONS
[1]
Enter the number of partitions (1-8) to be used in the system.
2*01 DAYLIGHT SAVINGS TIME START/END MONTH [04,10]
|
|
Enter the months (00-12) in which daylight savings time starts and ends.
Enter 00, 00 if daylight savings time does not apply to the user's region. Standard
setting for U.S. is 04,10.
2*02 DAYLIGHT SAVINGS TIME START/END WEEKEND [1,5]
Enter the start and end weekends for daylight savings time as follows: 1=first;
2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last. Standard setting
for U.S. is 1,5.
U
L
Fields 2*05 – 2*08 must be set to 0 for UL installations.
2*05 AUTO-ARM DELAY (partition-specific) [15]
|
Enter the time between the end of the arming window and the start of auto arm
warning time in values of 01-14 times 4 minutes.
Enter 00 if no delay is desired.
Enter 15 if auto arming is not desired.