VISTA-128B Installation Instructions
11-2
As part of its fail-safe software, the control will limit all audio alarm verification sessions to
15 minutes. This is because once the session begins, the AAV Module controls the duration.
If a new fire alarm should occur during a session, the control will break the phone connection
and send the new Fire Alarm report, then re-trigger the AAV Mode. All other dialer
messages triggered during ongoing conversation will be held until either the AAV Module
signals that it is inactive, or the 15-minute timeout occurs.
One way to trigger the AAV Module is by selecting option 3 in field 1*46 and make
connections as shown in Figure 11-1a. Field 1*46 can be used to set ground start, remote
console sounding, long range radio, or open/close trigger. If any one of these functions are
absolutely necessary in a given installation, the alternative AAV trigger method is via the
use of a 4204 Relay Module as shown in Figure 11-1b. If this method is selected, program the
start and stop conditions for that relay as choice 60 "Audio Alarm Verification" during Relay
Programming in the #93 Menu Mode.
Some AAV Modules allow remote triggering by ring detection at the alarm installation.
Please be advised that if this option is selected, it may defeat modem download and
4285/4286 VIP Module remote access capability. The DIP switch settings shown in Figures
11-1a, b and c disable remote AAV Module trigger option. The control requires the AAV
Module trigger-type as falling edge, which is set in DIP switch settings shown.
1. 685 Receiver software must be rev. 4.6 or higher. Earlier versions will not hold the phone line
connection.
2. Contact ID code for “Listen-in-to-Follow” is 606. Contact ID is the only reporting format that will
send a "Listen-in-to-Follow."
Audio Alarm Verification Module Connections
Connect the Audio Alarm Verification Module's falling edge trigger input (terminal 5 on
Eagle model 1250) to J7 connector trigger output, or to a 4204 relay module, as shown in
Figures 11-1a, b and c.
If also using a 4285/4286 VIP Module, be sure to follow the corresponding diagram when making
connections.
If the phone plug is disconnected from the control, the premise’s phones will not operate.