VISTA-128B Installation Instructions
12-4
Wiring for the Remote Keypad Sounder
Connect the piezo sounder to the panel’s positive auxiliary power output and to Output 1 on
the J7 connector as shown in Figure 12-3.
1 2 3 4 5 6 7 8 9
GRAY
YELLOW
WHITE
RED
GREEN
BROWN
BLUE
BLACK
GROUND
OUT 1
GROUND
OUT 2
GROUND
OUT 3
GROUND
OUT 4
J7 CONNECTOR
IF USED.
1. OUT 1 IS NO LONGER
USABLE FOR OPEN/CLOSE
OR GROUND START (SEE
FIELD 1*46).
2. OUT 2, 3, 4 CAN STILL BE
USED TO PROVIDE ALARM
STATUS INDICATIONS OR
TO OPERATE A KEYSWITCH
(SEE FIELD *15).
N/U
4142TR CABLE
BLACK
AMSECO PAL-328N
PIEZO SOUNDER
+
RED
TO AUX POWER +
TERMINAL 6
(10mA CURRENT DRAW)
Figure 12-3: Remote Keypad Sounder Wiring
Programming for the Remote Keypad Sounder
1. With at least one 2-line alpha keypad (6139) wired and set to a proper address, power up
the system temporarily by plugging the AC transformer into a 120VAC outlet (previously
wired to the control).
2. Enter Data Field Programming Mode: [Installer Code] + 8 0 0 0.
Program the following data field:
1*46 AUXILIARY OUTPUT ENABLE: Set to "1"
3. Press *99 to exit Program Mode.
Remote Keyswitch Operation and Wiring
An optional UL-Listed remote keyswitch, such as the ADEMCO 4146, can be used for remote
arming/disarming of the burglary portion of the system and for remotely silencing alarms.
The keyswitch can operate in only one particular partition.
Wiring for the Remote Keyswitch
Wire the keyswitch as shown in Figure 12-3. The tamper switch need not be used for fire or
UL household burglary installations. For UL commercial burglary installations, the tamper
switch must be wired to zone 8, and zone 8 must be programmed for day trouble/night alarm
(zone type 5). When the keyswitch is removed from the wall, the tamper switch will open,
causing an alarm or trouble on zone 8, and causing the control to disable keyswitch operation
until the associated partition is disarmed from a keypad.