31
START STOP
ACTION DESIRED A E V Z L Z T P Z L Z T P
UNLOCK EXIT DOORS
Close relay on Burg alarm, reset with entry of security
code + # + 7 + 1
21X33XX34X
Close relay on Fire alarm, reset with entry of security code
+ # + 7 + 1
21X09XX34X
TURN ON EMERGENCY LIGHTING
An AC loss detection causes relay to close for 2
seconds.*
10041X000X
*The relay will not reset on restoral of low battery or AC
power. For this reason, using "close for 2 seconds" in
A(action) is recommended.
SOUNDING FOR WIRELESS KEYPAD
Pulse relay at start of entry time and reset when system is
disarmed (entry warning)*
30032X022X
*Relay can be used to turn on an external sounder placed
where it can be heard by someone using the wireless
keypad.