2*19 Use Partition Descriptors
Enter 1 if partition descriptors will be programmed. If enabled, the normal
console display will include a partition number and the partition descriptor (if
programmed in #93 Menu Mode). Entering 0 causes the consoles to
display a non-partitioned system type of display (no partition no. appears).
Scheduling & Relay Output
Options
Second Page Fields
1*74 Relay Timeout XX Minutes
Enter the relay timeout, 0-127 in multiples of 2 minutes, desired for #80
Menu Mode time driven event relay command numbers "04/09" and #93
Menu Mode Relay Programming output command "56" (refer to #93 and
#80 Menu Mode sections in this manual).
1*75 Relay Timeout YY Seconds
Enter the relay timeout, 0-127 seconds, desired for #80 Menu Mode
time driven event relay command numbers "05/10" and #93 Menu Mode
Relay Programming command "57" (refer to #93 and #80 Menu Mode
sections in this manual).
Third Page Fields
2*01 Daylight Savings Time Start/End Month
Enter the months 00-12 in which daylight savings time starts and ends.
Enter 00, 00 if daylight savings time does not apply to the user's region.
Standard setting for U.S. is 04,10.
2*02 Daylight Savings Time Start/End Weekend
Enter the start and end weekends for daylight savings time as follows:
1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from
last. Standard setting for U.S. is 01,05.
2*11 Allow Disarm Outside Window If Alarm Occurs
Used only if field 2*10 (partition-specific field) is set to 1. Enter 1 if it is
desired that the system can be disarmed outside the programmed disarm
window if an alarm has occurred. Enter 0 if it is desired that disarming can
only be done during the disarm window, regardless of system status. If field
2*10 is set to 0 for a partition, this field (2*11) has no effect for that partition.
2*13-2*14 Scheduling Related Dialer Reports
Enter the report codes for the scheduling related events as shown on the
programming form.
Event Logging Options 1*55 Date Format Selection
Select the desired date format where 0 = mmddyy; 1 = ddmmyy
1*56 60Hz/50Hz Real Time Clock Synchronization
Enter the appropriate value where 0 = 60Hz Mains; 1 = 50Hz Mains.
1*70 Event Log Types
Enter 1 for each of the types of events for which event logging is
desired, as shown on the programming form. Otherwise enter 0.
1*71 12/24 Hour Time Stamp Format
Select the type of time stamping desired: 0=standard 12 hour; 1= 24
hour format.
1*72 Event Log Printer On-Line
Enter 1 to enable the printer to print events as they occur, or 0 to enable
the printer such that the logs are only printed upon request.
1*73 Printer Baud Rate
Enter 0 if printer is configured for 1200 baud (preferred). Enter 1 if printer
is configured for 300 baud.
Alarm Verification 1*60 Alarm Verification
Enter 1 if alarm verification is used. Otherwise enter 0.
1*66 Silence Bells During Alarm Verification
Enter 1 if audio alarm verification is used. Otherwise enter 0.
1*67 Video Alarm Verification Selection
Enter 1 if video alarm verification is used. Otherwise enter 0.