The following table describes each format in greater detail.
FORMAT TYPE DESCRIPTION
3+1 and 4+1
Standard Formats
Comprises a 3- (or 4-) digit subscriber number and a single-digit report
code (e.g., Alarm, Trouble, Restore, Open, Close, etc).
3+1 and 4+1
Expanded Formats
Comprises a 3- (or 4-) digit subscriber number and a two-digit report code.
The first digit is displayed on the first line. On the second line, it is
repeated 3 (or 4) times and is followed by the second digit. This is the
“expanded” digit.
4+2 Format Comprises a 4-digit subscriber number and 2-digit report code.
ADEMCO Contact ID
Reporting Format
Comprises a 4-digit subscriber number, 1-digit event qualifier (“new” or
“restore”), 3-digit event code, and 3-digit zone number, user number, or
system status number (see the following page).
The following table lists codes for reports sent in different formats:
Code for Code for
Type of 3+1/4+1 3+1/4+1
Code for
Report Standard Expanded 4+2
Alarm SSS(S) A SSS(S) A SSSS AZ
AAA(A) Z
Trouble SSS(S) T SSS(S) T SSSS Tt
TTT(T) t
Bypass SSS(S) B SSS(S) B SSSS Bb
BBB(B) b
AC Loss SSS(S) E SSS(S) E SSSS EA
C
EEE(E) A
C
Low Batt SSS(S) L SSS(S) L SSSS LL
B
LLL(L) L
B
Open SSS(S) O SSS(S) O SSSS OU
OOO(O) U
Close SSS(S) C SSS(S) C SSSS CU
CCC(C) U
Test SSS(S) G SSS(S) G SSSS Gg
GGG(G)g
Restore SSS(S) R SSS(S) R SSSS RZ
Alarm RRR(R) Z
AC Restore SSS(S) R
A
SSS(S) R
A
SSSSR
A
A
c
R
A
R
A
R
A
(R
A
)A
c
LoBat Res. SSS(S) R
L
SSS(S) R
L
SSSS R
L
L
B
R
L
R
L
R
L
(R
L
)L
B
Trouble Res. SSS(S) R
T
SSS(S) R
T
SSSS R
T
t
R
T
R
T
R
T
(R
T
)t
Bypass Res. SSS(S) R
B
SSS(S) R
B
SSSS R
B
b
R
B
R
B
R
B
(R
B
)b
Where:
SSS or SSSS = Subscriber ID C = Close Code–1st Digit
A = Alarm Code–1st digit U = User Number (in hex)
Z = Typically Zone Number*–2nd digit Gg = Test Code (1st & 2nd digits)
Tt = Trouble Code (1st & 2nd digits) R = Restore Code (Alarm)
Bb = Bypass Code (1st & 2nd digits) R
T
t = Restore Code (Trbl) 1st & 2nd digits
EA
C =
AC Loss Code (1st & 2nd digits) R
B
b = Restore Code (Byps) 1st & 2nd digits
LL
B =
Low Battery Code (1st & 2nd digits) R
A
A
C
= Restore Code (AC) 1st & 2nd digits
O = Open Code–1st Digit R
L
L
B =
Restore Code (Bat) 1st & 2nd digits
*Zone numbers for:
✱
& #, or B = 99 1 +
✱
, or A = 95 Duress = 92
3 + #, or C = 96 Tamper = 9