
VISTA-15/VISTA-15CN Installation and Setup Guide
15–8
SYSTEM STATUS
REPORT CODES
✱
59–
✱
68)
✱
59 EXIT ERROR REPORT CODE
(See previous page)
0
If the system is armed and an Entry/Exit or Interior zone
†
is still open after the
Exit Delay time has expired, an alarm sounds at the keypad and external
sounder (keypad also displays EXIT ALARM). If the system is disarmed before
the end of the Entry Delay that immediately follows, the alarm sounding stops
and no message is sent to the Central Station. The keypad displays CA (fixed-
word keypads) or CANCELED ALARM (alpha keypads).
If the system is not disarmed before the end of the entry delay mentioned
above, and an entry/exit or interior zone is still open, an “Exit Alarm” message
is sent to the Central Station if an Exit Error
Report code
is selected in this
field. The keypad displays EA (on fixed-word keypads) or EXIT ALARM (on
alpha keypads), and the alarm sounding continues until the system is disarmed
(or timeout occurs).
An Exit alarm condition also results if a fault occurs in an exit or interior zone
within 2 minutes following the end of the exit delay, and an “Exit Alarm”
message is sent to the Central Station.
If Contact ID format has been programmed, the message contains the zone
number and error code 374 (“Trouble–Exit Error”) to define the alarm as an
Exit Error (rather than E/E or Interior). If 4+2 format is used, the digit entered
in this field is sent followed by the second digit of the programmed alarm code
for that zone. If 3+1 or 4+1 format is used, only the digit entered in this field is
sent. This message goes to the primary phone number. Under any of these
conditions, no “Restore” message is sent.
If 0 is entered in this field, no special message is sent, only the regular Alarm
and Alarm Restore code for the zone.
✱
60 TROUBLE REPORT CODE
(See previous page)
0 | 0
This is sent if a zone goes into trouble, if zone is shorted and hardwire
short detection is enabled, or if only one zone in a cross-zone list is
faulted during the cross zone time while the system is armed.
✱
61 BYPASS REPORT CODE
(See previous page)
0 | 0
This is sent when a zone is manually bypassed (or forcibly bypassed
as programmed in
✱
23).
✱
62 AC LOSS REPORT CODE 0 | 0
See box on previous page. Reports with subscriber number. Timing of this
report is random with up to a 4-hour delay. If AC restores before the report
goes out, there is no “AC Restore” report.
✱
63 LOW BAT REPORT CODE 0 | 0
This is sent when a low-battery condition exists in the system’s standby
battery. See box on previous page. Reports with subscriber number.
✱
64 TEST REPORT CODE
0 | 0
This is sent periodically to test that the communicator and phone lines are
operational (frequency of report is selected in field
✱
49).
See box on previous
page.
Reports with subscriber number.
✱
65 OPEN REPORT CODE 0
This is sent upon disarming of the system. See box on
previous page.
Second
digit is user number, if Expanded or 4+2 reporting is selected.
†
Entry/Exit or Interior zones in the Cross Zoning List (Zone List 04) or
Interior zones in the Night-Stay List (Zone List 05), may react in a different
manner. Refer to
Section 18: Zone Lists
.
Komentáře k této Příručce