VISTA-15/VISTA-15CN Installation and Setup Guide
15–12
✱
88 PAGER CHARACTERS
When programmed in field
✱
47, reports are sent to the pager depending upon
the number selected.
| | | | | | | | | | | | | | |
This programming field (
✱
88) allows up to 16 digits to be entered to signal a
pager
. For example, These optional 16 digits may be composed of the
following:
•
PIN number (to identify a specific pager to the paging company)
•
subscriber account number
•
✱
(enter # + 11 to
send
✱
)
•
# (enter # + 12 to
send
#
)
•
pause (enter # + 13 to allow a 2-second pause)
•
any special character(s) the end user may decide to transmit
All 16 digits do not have to be used.
The preceding 16 digits (if any) are followed by a 7-digit Pager Format,
which is defined as follows: | | | | | |
Pager Format: XXX-YYYY
where:
XXX = a 3-digit event code:
911 = Alarm 101 = Opening (disarm)
811 = Trouble 102 = Closing (arm AWAY)
YYYY = user or zone number (depending on type of event)
The first two digits must always be 00, and must be followed by the 2-digit
user or zone number. Paging is enabled in the Split/Dual Reporting field
✱
47
by entering a number greater than 5.
NOTE: Some pagers may require an additional delay (pause) to be
programmed into this field in order to receive the entire message. Field
✱
87
provides an optional pager reporting delay of 0, 1, 2, or 3 minutes for alarm
messages only. Enter
# + 13
for a 2-second pause.
✱
89 EVENT LOG 80% FULL REPORT CODE
0 | 0
If an Event Logging selection is made in field
✱
90, a message can be sent to
the Central Station receiver when the log is 80% full. If the log becomes full, a
new message
overwrites
the oldest message in the log.
NOTE:
Aside from the
selection
made by the installer in field
✱
90, all control
and readout from the log is accomplished via the downloader.