VISTA-15/VISTA-15CN Installation and Setup Guide
15–4
36 ENTRY DELAY 2
2
0 = 30-second delay 4 = 120-second delay
1 = 45-second delay 5 = 180-second delay
2 = 60-second delay 6 = 240-second delay
3 = 90-second delay
The system waits the time entered before it sounds an alarm upon entering.
UL installations: Must be set for a maximum of 45 seconds
37 AUDIBLE EXIT WARNING
1
0 = no exit warning sound
1 = provide exit warning sound when armed AWAY or MAXIMUM
Warning sound consists of slow continuous beeps until last 10 seconds, when
it changes to fast beeps. The warning sound ends at the termination of Exit
time.
38 CONFIRMATION OF ARMING DING
0
0 = no ding
1 = confirmation ding after arming system
2 = confirmation ding after arming from RF button or RF keypad only (ding
occurs when the system receives the RF transmission)
Confirmation of arming is ½-second external sounder “ding” when closing
report is sent, or at the end of Exit Delay.
39 POWER UP IN PREVIOUS STATE
1
0 = always power up in a disarmed state
1 = assume the system status prior to power-down
When the system powers up armed, an alarm occurs 1 minute after arming if
a zone is faulted.
Note that if the previous state was armed AWAY, STAY, NIGHT-STAY,
INSTANT, or MAXIMUM, the system does not respond to sensor changes for
1 minute, which allows time for sensors such as PIRs to stabilize.
UL installations: Must be 1 (power up in previous state).
DIALER
PROGRAMMING
(
40–
52)
40 PABX ACCESS CODE
(See box at left)
| | | | |
Enter up to 6 digits if PABX is needed to access an outside line. If fewer than
6 digits need to be entered, exit by pressing [
]
and next field number
(e.g.,41). To clear entries from field, press
40
.
41 PRIMARY PHONE NO.
(See box at left)
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. If you enter fewer than 20 digits, exit by pressing
[
]
and next field number (e.g., 42). To clear entries from field, press
41
.
NOTE:
Backup reporting (in which 8 calls are made to the secondary phone
number if no kissoff is received after 8 attempts to the primary number) is
automatic only if there is a secondary phone number (field
42).
Fields
40,
41,
42:
Enter up to the number
of digits shown. Do not
fill unused spaces.
Enter 0–9,
# + 11 for
# + 12 for #
# + 13 for a pause
(2 seconds)
42 SECONDARY PHONE NO.
(See box at left)
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. If you enter fewer than 20 digits, exit by pressing
[
]
and next field number (e.g., 43). To clear entries from field, press
42
.
See backup reporting note for field
41. If using the pager feature, enter the
pager phone number here.