Section 22 - System Operation
22–3
If you armed the system using the [C] (NIGHT-STAY) key, your only option is to use the
[A] (AWAY) key to increase the level of security. (These lettered keys must be pressed
and held down for a minimum of 2 seconds).
The [A], [B], and [C] keys are disabled for panic operation.
These arming-level changes transmit an Opening report followed by the appropriate
report of the armed state to the Central Station. The security code is always required,
however, when disarming the system.
When an alarm occurs,
keypad
sounding and
external sounding occur, and the zone(s) in alarm are displayed on the keypad. Pressing
any key silences the keypad sounder for 10 seconds. Disarming the system silences both
keypad and external sounders. When the system is disarmed, any zones that were in an
alarm condition during the armed period are displayed. To clear this display, simply
repeat the disarm sequence (enter the security code and press the OFF key) again.
The interior zones (Interior or Interiors with Delay), have the following characteristics:
Armin
g
Mode Interior Zones Interior Zones in Zone List 05
STAY
B
y
passed Does not appl
y
NIGHT-STAY
B
y
passed Armed
SUMMARY OF ARMING MODES
Features for Each Arming Mode
Arming
Mode
Exit Delay
Entry Delay
Perimeter Armed
Interior Armed
STAY
Yes Yes Yes No
NIGHT-STAY
Yes Yes Yes Yes (if in Zone List 05)
INSTANT
Yes No Yes No
AWAY
Yes Yes Yes Yes
MAXIMUM
Yes No Yes Yes
The VISTA-15/VISTA-15CN contains an Exit Delay Reset feature that allows the user to exit (fault), close the
door (restore the fault), then re-enter (fault again) the premises within the exit delay time period. Upon re-
entering, a new exit delay time period is begun with the keypad annunciating three rapid beeps. This feature
only resets the exit delay one time for each arming session.
PANIC Keys
There are three PANIC key pairs,
OR
(on keypads 6128 and 6139 keypads if Quick Arm is
disabled in field
21), lettered keys that can be used to manually initiate alarms and send a
report to the Central Station. Lettered keys can only initiate the alarms if Quick Arm (field
21) is disabled.
Each can be individually programmed for 24-hour Silent, Audible, Personal, or Fire
Emergency responses. The Panic function is activated when both keys of the appropriate key
pair are pressed at the same time, or the appropriate lettered key is pressed for at least 2
seconds.
The Panic functions are identified by the system as follows:
Keys Displayed as Zone
1 +
,
or
A
95
+ #,
or
B
99
3 + #,
or
C
96
D
Pager Msg is Sent
Notes:
Keys A, B, and C are not on all keypads
as indicated.
Key D, if present, with pager enabled in
field
47, sends a 999-9999 message to
the pager. The message signifies
ANY
message the user and recipient have
decided is appropriate, and is
independent of the Quick Arm field.
Important:
For the Silent Panic functions to be of practical value, the system must be
connected to a Central Station.