Section 13 - Mechanics of Programming
13–3
Loading Factory Defaults
To load the factory defaults, enter the Programming mode, press
✱
97, then exit the
Programming mode.
Do not press
✱
97 to load defaults if any programming has been done previously—data already
programmed into the system will be changed!
✱
96 resets all the subscriber account numbers and CSID in preparation for an initial
download.
Programming System Setup Fields
The following program fields must be programmed before doing any zone programming:
✱
22 RF SYSTEM
0
Enter
1
if 5881 RF Receiver without RF Jam Detection is being used; enter
4
if
5881/5882 RF Receiver with Jam Detection is being used; if no RF receiver is being
used, enter
0
(the default value).
✱
25
WIRED ZONE EXPANSION
0
Use this field to select the type of expansion unit being used, as follows:
0 = none; 1 = 4219; 2 = 4229; 3 = 4204. Default is
0.
Exiting the Programming Mode
✱
99 allows re-entry into the Program mode using Installer Code + 8 0 0.
✱
98 prevents re-entry into the Programming mode using the Installer code.