Section 13 - Mechanics of Programming
13–3
Loading Factory Defaults
To load the factory defaults, enter the Programming mode, press
97, then exit the
Programming mode.
Do not press
97 to load defaults if any programming has been done previously—data already
programmed into the system will be changed!
96 resets all the subscriber account numbers and CSID in preparation for an initial
download.
Programming System Setup Fields
The following program fields must be programmed before doing any zone programming:
22 RF SYSTEM
0
Enter
1
if 5881 RF Receiver without RF Jam Detection is being used; enter
4
if
5881/5882 RF Receiver with Jam Detection is being used; if no RF receiver is being
used, enter
0
(the default value).
25
WIRED ZONE EXPANSION
0
Use this field to select the type of expansion unit being used, as follows:
0 = none; 1 = 4219; 2 = 4229; 3 = 4204. Default is
0.
Exiting the Programming Mode
99 allows re-entry into the Program mode using Installer Code + 8 0 0.
98 prevents re-entry into the Programming mode using the Installer code.